The purpose of the document is to specify the functional requirements of Power Delivery,PD 18W *2 Output, Support Meet USB Power Delivery(PD3.0)、QC3.0/2.0, DCP BC1.2、APPLE , SAMSUNG、MTK PE+1.1、FCP、SCP Equipment charging
Output voltage and current
Output Voltage | Output current | Min. Load | Rated. Load | Full load Voltage | Output power | ||
TYPE C/PD1 | 5V | 3A | 0A
| 3A | 4.7-5.25V | 18W MAX | |
9V | 3A | 2A | 8.45-9.45V | ||||
12V | 3A | 1.5A | 11.4-12.6V | ||||
TYPE C/PD2 | 5V | 3A | 3A | 4.75-5.25V | 18W MAX | ||
9V | 2A | 2A | 8.45-9.45V | ||||
12V | 1.5A | 1.5A | 11.4-12.6V |
INPUT CHARACTERISTICS:
2.1Input Voltage:
/Rated Voltage:100~240Vac
Variation Range:90-264Vac
2.2Input Frequency:
Rated Frequency: 50/60Hz.
Variation Frequency:47-63Hz
2.3Input Current:
1.0Amps max At any input voltage and rated, DC output rated load.
3.PROTECTION FUNCTION:
3.13Short circuit test:
The power supply will be auto recovered when short circuit faults remove.
3.2Over current Protection:
The power supply will be auto recovered when over current 4A Max faults remove.
3.3Over Voltage Protection:
The power supply will auto recovered when faults remove 130%~150%.
Meet:CE,FCC,CCC,UL/CUL
Output voltage and current
Output Voltage | Output current | Min. Load | Rated. Load | Full load Voltage | Output power | ||
TYPE C/PD1 | 5V | 3A | 0A
| 3A | 4.7-5.25V | 18W MAX | |
9V | 3A | 2A | 8.45-9.45V | ||||
12V | 3A | 1.5A | 11.4-12.6V | ||||
TYPE C/PD2 | 5V | 3A | 3A | 4.75-5.25V | 18W MAX | ||
9V | 2A | 2A | 8.45-9.45V | ||||
12V | 1.5A | 1.5A | 11.4-12.6V |
INPUT CHARACTERISTICS:
2.1Input Voltage:
/Rated Voltage:100~240Vac
Variation Range:90-264Vac
2.2Input Frequency:
Rated Frequency: 50/60Hz.
Variation Frequency:47-63Hz
2.3Input Current:
1.0Amps max At any input voltage and rated, DC output rated load.
3.PROTECTION FUNCTION:
3.13Short circuit test:
The power supply will be auto recovered when short circuit faults remove.
3.2Over current Protection:
The power supply will be auto recovered when over current 4A Max faults remove.
3.3Over Voltage Protection:
The power supply will auto recovered when faults remove 130%~150%.
Meet:CE,FCC,CCC,UL/CUL